(firmenpresse) - Creating a comfortable and at the same time pure indoor climate in industrial halls involves high costs, especially in the winter months. However, a pleasant room temperature is essential for the performance of the employees, the protection of temperature sensitive products and the smooth run of production processes. The central extraction and filter unit AIRTECH by TEKA provides an effective solution. The room ventilation solution for the filtration of workshop air is now available with a heating grid and is thus able to warm up the air and to additionally purify them from fumes and dusts.
The device is permanently installed in the workspace and sucks up the polluted air via side canals and filters it. Afterwards the purified air flows through the heating grid. It is integrated into the pneumatic section of the unit and connected to the existing heating boiler.

The AIRTECH is particularly energy-saving thanks to the combination of several characteristics. Firstly: The cleaning efficiency of the filters of the dust category M is close to 100 %. The purified warm air can be led back into the hall instead of being led outside. Devices that supply and heat up fresh air are mostly dispensable. Secondly: The heating grid can serve as a frost protection, especially in countries with temperatures far below zero. If the user has no or no powerful heating system in his hall, he can use the module as an alternative or as an addition to heat up the air to the desired temperature. Thirdly: The pivoting nozzles carry the purified warm air up to 40 metres back into the hall. The warm air spreads evenly in the room thanks to the air circulation. Thus energy and heating costs can be reduced effectively.

In practice this could be as follows: TEKA has equipped a hall with three extraction and filter units of the AIRTECH P18 type with integrated heating grids in the metal-processing company RosNefteKomplekt in Russia. The units have an air-flow rate of 18.000 m³/h each. They are designed in a way that the air temperature is increased by 6 °C at the exit into the hall. Therefore an effective performance of 35 kW and a supply temperature of 70 °C is needed. In principle much higher air outlet temperatures can be reached depending on the individual heat demands of the user. Each individual case depends on factors such as the size of the hall, the thermal insulation and the air-change rate.




Weitere Infos zu dieser Pressemeldung:
Unternehmensinformation / Kurzprofil:

About TEKA:
TEKA Absaug- und Entsorgungstechnologie GmbH was founded in 1995 by the general managers Jürgen Kemper and Erwin Telöken. The company ranks among the European leading manufacturers of extraction and filter units for the industrial, craft and laboratory sector. The company producing for the worldwide market has about 120 employees. The product portfolio not only contains mobile and stationary extraction and filter units, but also oxygen cutting benches, vision protection and soundproofing elements.



drucken  als PDF  an Freund senden  Desert Eagle: New Stainless Steel Model SM InnoTech receives new order for the manufacturing of Stack-Laminators
Bereitgestellt von Benutzer: Katrin Herbers
Datum: 20.02.2015 - 10:10 Uhr
Sprache: Deutsch
News-ID 373040
Anzahl Zeichen: 2457

contact information:
Town:

Velen


Phone: +49286392820

Kategorie:

Energy & Utilities


Typ of Press Release: Produktinformation
type of sending: Veröffentlichung
Date of sending: 20.02.2015

Diese Pressemitteilung wurde bisher 339 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"Extraction unit with heating grids cleans and heats up the air in the hall"
steht unter der journalistisch-redaktionellen Verantwortung von

TEKA Absaug- und Entsorgungstechnologie GmbH (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).

Pure air when welding large components ...

How can welders be protected against hazardous particles in the air when working with large components at frequently changing workplaces? Extraction and filter units that capture the polluted air precisely and filter it are the solution. But conventi ...

Practical test passed ...

Several welders are working on a long steel beam in the production hangar at Peters Stahlbau. Sparks are flying, smoke is rising. A few metres away general manager Heinz-Geert Peters is observing the events and is taking a deep breath. He can do this ...

Alle Meldungen von TEKA Absaug- und Entsorgungstechnologie GmbH



 

Werbung



Facebook

Sponsoren

foodir.org The food directory für Deutschland
Informationen für Feinsnacker finden Sie hier.

Firmenverzeichniss

Firmen die firmenpresse für ihre Pressearbeit erfolgreich nutzen
1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z