German office for energy is getting lots of tailwind

German office for energy is getting lots of tailwind

ID: 247845
Blower Door World recordBlower Door World record

(firmenpresse) - Europeans biggest closet is coming under scrutiny: Christian Rösemeier, CEO of „energiebüro q50 Rösemeier" (office for energy) is currently planning the biggest Blower Door Test of all times. The Expert-Team for energy from Lower-Saxony, Germany (Hameln), wanted to set a new world-record with a Blower Door Test at the stock of a popular mail order company in Erfurt.

Facts
The building measures 192 times 528 meters, has a base area of 101.400 square meters, is 13,5 meters high and has a volume of 1.346.800 cubic meters. A big deal - not only for the Investor Goodman Cinnamon/Boysenberry Logistics (Lux) S.a.r.l.. "With this Blower Door Test we want to get an entry in the Guinness Book of World Records", says Christian Rösemeier. On Sunday the 14th April he and his team are travelling with more than 30 Blower Dower compressors to Erfurt.

The pure test takes ten to twelve hours. Under the direction of "energiebüro q50", the "Danilo Kauer Trockenbauservice" (Dry Wall Installation) will bring the building into condition of measuring. A big gun, too: Germanys biggest Blower Door compressor with a 40 PS-gas engine from "energiebüro q50", is going to be used together with the Minneapolis Compressors. Christian Rösemeier has imported the machine from the USA. The compressor has a volume flow rate about more than 130.000 cubic meters per hour. That knocks socks off: the entire volume flow rate of every compressor is at large 400.000 cubic meters per hour. Pre measurements inclusive, the "energiebüro q50" was visiting Erfurt two times to assess the total expenditure and to make first preparations.

What about Blower Door Tests?
The Blower Door Test is one of the most important instruments for energy efficiency, in times of rising energy costs and climate change. With a Blower Door Test you can measure the airtightness of a building. It serves for detecting leaks in building envelopes and to determine the air exchange rate, in order to eliminate structural damages while the construction phase. The air-impermeability of buildings is stipulated in the Energy Saving Enactment of the German Government, to avert leaks in new buildings. So the Blower Door Test is important for business companys such as for private house owners. No matter if new buildings or rehabilitations.





During the Blower Door Test, ventilators will be build into exterior doors. Depending of the building-size, the amount of ventilators is varying. All openings which are conducting to the outside, have to be closed. All internal doors have to be open. By using the ventilators, (Blower Door) air is getting extracted out of the building through an indiscernible vaccum. If the outer shell of the building is permeable, ambient air is pouring into the inside. Depending on the air, which is getting extracted through the outside, the more the building is permeable.

Men of action
The "energiebüro q50" is certified for ISO 20807 (air-proofness-testing on buildings) and is licensed to accomplish Blower Door Tests Europe-wide. CEO Christian Rösemeier is certified by the Fachverband für Luftdichtheit e. V. (Professional Association of Air-Tightness) as defined by the Energy Saving Enactment. A six-headed Team is planning, preparing and accomplishing. Even at the weekend or in the night according to costumer requests. Measuring gauges of the new generation are in use Europa-wide as well as subject-specific Hard- and Software. From the order entry to the precise measures and proposals for solutions, the secure and efficient accomplishment is guaranteed. Consulting and service such as application and documentation of the results by "energiebüro q50"are one-stop. Trainings in airtightness, building physics and building equipment strategy are expanding the business activities of "energiebüro q50".

And if the powerful 40-PS compressor is getting started on Sunday, the 14th April, at the stock in Erfurt, Christian Rösemeier and his team will stop breathing for a few seconds. The results of the analyses are landing at the Guinness World Records in London just a little later.

Weitere Infos zu dieser Pressemeldung:

Themen in dieser Pressemitteilung:


Unternehmensinformation / Kurzprofil:

Specialists of blower door tests of office and industrial buildings (DGNB projects) and blower door measurements of large buildings over 5,000,000 m³. We measure EU-wide for you.



drucken  als PDF  an Freund senden  Viral vectors for novel cell models, gene therapy and vaccine development gain further funds from private investors JPK reports on the research activities of the Nanophysics Group at the Istituto Italiano di Tecnologia based in Genova
Bereitgestellt von Benutzer: ebq50
Datum: 10.04.2013 - 19:41 Uhr
Sprache: Deutsch
News-ID 247845
Anzahl Zeichen: 4207

contact information:
Contact person: Christian Rösemeier
Town:

Hess. Oldendorf


Phone: 04951589939224

Kategorie:

Handcrafts


Typ of Press Release: Unternehmensinformation
type of sending: Veröffentlichung

Diese Pressemitteilung wurde bisher 370 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"German office for energy is getting lots of tailwind"
steht unter der journalistisch-redaktionellen Verantwortung von

energiebüro q50 christian rösemeier (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).


Alle Meldungen von energiebüro q50 christian rösemeier



 

Werbung



Facebook

Sponsoren

foodir.org The food directory für Deutschland
Informationen für Feinsnacker finden Sie hier.

Firmenverzeichniss

Firmen die firmenpresse für ihre Pressearbeit erfolgreich nutzen
1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z