(PresseBox) - Standard  VDE-AR-N 4105 covers systems which are directly connected to grid: photovoltaic systems, CHP plants (combined heat and power units), wind and hydro power generation units, Stirling generators, fuel cells and asynchronous generators. It applies to generators with a total maximum active power (? PAmax) of up to 135 kW, independent of the network LV or MV voltage levels

The latest VDE-AR-N 4105: 2018-11 defines the dynamic grid stabilization. The network stability or isolation from the grid must also be secured if any voltage sags or peaks should occur.

Providing the input voltage is within the parameters of the generating unit or voltage storage, system disconnection must not occur in less than 3 seconds.

Equally in the event of any under voltage, coupling switches  must remain energized for three seconds to compensate for any power system events such as voltage transients.

As long as the input voltage is within the defined voltage range of the generating unit, or the storage, disconnection from the system grid must not occur.

SOLUTION:

Using the J Schneider, Online Dynamic Grid Stabilization (ODGS) the following generating and storage solutions are comfortably achieved as follows:

Avoidance of under voltage malfunctions, as ?ONLINE? capacitor based a UPS system is employed to ensure the operation of coupling switches or contactors. This ?Online? system ensures a continuous power supply without any potential interruption due to power failure. The unique and well proven J Schneider, Type AC C-TEC and C-TEC series devices are well acknowledged as the solution.

TECHNICAL DATA

The J Schneider Capacitor based UPS systems offer

Long life and maintenance-free operation thanks to durable ultra-capacitors

Type tested, operating temperature range from -40°C up to +60°C

Microcontroller-based charging and discharging of the ultra-capacitors





Operating and charge status monitoring via floating contacts and LEDs

Capacity easily expandable with use of external capacitor modules (CEM)

Energy range from 500 Joule through to 20 k Joule

Extensive product range ratings from 3 A DC up to 40 A DC

Input voltage 1 ph / 3 ph or 12 V DC / 24 V DC / 48 V DC

Output voltage 12 V DC / 24 V DC / 48 V DC

 

 

High-precision handling of currents, voltages and drive technology characterises J. Schneider Elektrotechnik. In close consultation with the customer, tailor-made solutions and series products are developed in the product areas

- Transformers

- Uninterruptible Power Supplies

- High voltage and plasma power supplies

- Service Center electric drives

Customer orientation and quality are the basis for development and production in all areas.

Founded in 1939, the company now employs more than 360 people in three plants in Offenburg, Germany. With mutual respect and a high level of social responsibility, they develop and manufacture future-proof solutions at the cutting edge of technology with and for customers.

Weitere Infos zu dieser Pressemeldung:
Unternehmensinformation / Kurzprofil:

High-precision handling of currents, voltages and drive technology characterises J. Schneider Elektrotechnik. In close consultation with the customer, tailor-made solutions and series products are developed in the product areas- Transformers- Uninterruptible Power Supplies- High voltage and plasma power supplies- Service Center electric drivesCustomer orientation and quality are the basis for development and production in all areas.Founded in 1939, the company now employs more than 360 people in three plants in Offenburg, Germany. With mutual respect and a high level of social responsibility, they develop and manufacture future-proof solutions at the cutting edge of technology with and for customers.



drucken  als PDF  an Freund senden  Heinz Nowicki joins Bender Group as Chief Sales Officer Part 1 | What exactly does \'retrofit\' mean-
Bereitgestellt von Benutzer: PresseBox
Datum: 07.07.2020 - 13:27 Uhr
Sprache: Deutsch
News-ID 616088
Anzahl Zeichen: 3470

contact information:
Town:

Offenburg



Kategorie:

Research & Development



Diese Pressemitteilung wurde bisher 198 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"No Interruptions due to Power Failure in Low Voltage Grids"
steht unter der journalistisch-redaktionellen Verantwortung von

J. Schneider Elektrotechnik GmbH (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).


Alle Meldungen von J. Schneider Elektrotechnik GmbH



 

Werbung



Facebook

Sponsoren

foodir.org The food directory für Deutschland
Informationen für Feinsnacker finden Sie hier.

Firmenverzeichniss

Firmen die firmenpresse für ihre Pressearbeit erfolgreich nutzen
1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z