Explosionproof emergency stop device

Explosionproof emergency stop device

ID: 728413

Stop device


(PresseBox) -  

General

The purpose of the emergency stop device is to avert or prevent existing or impending risks to persons or damage to machines as a result of the behaviour of individuals or an unexpected hazardous event. The emergency stop device is triggered manually by a single action of a single person.

Explosionproof emergency stop devices are subject to both Directive 2014/34/EU (ATEX 114) and Machine Directive 2006/42/EC.

The emergency stop function must be designed in such a way that the decision to operate the emergency stop devices does not require the person to think about any consequences resulting from it.

The emergency stop devices must be permanently installed, so that it is easy for the operator to press in the event of danger. When pushbuttons are used, it should be possible to actuate them easily with the palm of one’s hand.

The emergency stop function must be available and operational at all times. It must have priority over all other functions and work processes in all types of operations of the machine without adversely affecting other protective functions.

The emergency stop function must be designed in such a way that, once the emergency stop devices has been actuated, any dangerous movements are stopped and the operation of the machine is suitably prevented without causing additional hazards and without any further intervention.

An electrical emergency stop device must apply the compulsory opening principle with a mechanical locking function. Electrical emergency stop devices meet the requirements of EN 60947-5-5.

Colours and texts

The button of the emergency stop device must be RED. If there is a background behind the actuator and inasmuch as it is realizable, this must be YELLOW.

Neither the control device nor the background of the control device is marked with a text or a symbol. If, for the sake of clarity, a symbol is required, the symbol must comply with IEC 60417-5638.





Resetting

If the emergency stop function has been activated:

it must be maintained until it is reset manually

a renewed starting of the work processes that were stopped by the initiation of the emergency stop function must not be possible.

The emergency stop function must be reset by a conscious act of one person. An emergency stop function must be reset by unlocking an emergency stop device. The reset must not initiate a restarting of the machine or installation.

The emergency stop function must not adversely affect the effectiveness of other safety functions.

Measures against unintentional activation

The emergency stop device must be designed in such a way that any unintentional activation is avoided. Measures against the unintentional activation of an emergency stop device must not create a risk of hindering the operation or the accessibility of the emergency stop devices. Provided that it is feasible, any unintentional activation must preferably be avoided by the arrangement than by constructional measures.

Certain precautions can be taken to avoid an unintentional activation, for example:

positioning the emergency stop device far from areas that are expected to be very busy,

selection of the type of emergency stop device,

selection of the suitable size and form of the emergency stop device, or

mounting the emergency stop device in a recessed surface of the surrounding control station.

The use of a protective collar around the emergency stop device to avoid any unintentional operation should be restricted to applications where other measures are not practicable.

A protective collar must not have sharp corners or edges or rough surfaces that could cause injury. Corners and edges must be deburred and the contact areas of surfaces must be smooth.

Hazardous areas in a wide range of process industries need reliable safety solutions when electrical equipment is in use. Nowadays the food, chemical, petrochemical, printing and power industries, manufacturers of aircraft and machinery, gas and oil producers, refrigeration engineers and other processoriented companies all rely on certified explosionproof equipment and components manufactured by thuba.

Weitere Infos zu dieser Pressemeldung:
Unternehmensinformation / Kurzprofil:

Hazardous areas in a wide range of process industries need reliable safety solutions when electrical equipment is in use. Nowadays the food, chemical, petrochemical, printing and power industries, manufacturers of aircraft and machinery, gas and oil producers, refrigeration engineers and other processoriented companies all rely on certified explosionproof equipment and components manufactured by thuba.



drucken  als PDF  an Freund senden  From Nanometers to Industry: High-Resolution 2PP 3D Printing Now in China Chips 4 Light: Cross-industry problem-solving expertise in LED technology
Bereitgestellt von Benutzer: PresseBox
Datum: 04.11.2025 - 09:00 Uhr
Sprache: Deutsch
News-ID 728413
Anzahl Zeichen: 4484

contact information:
Contact person: Peter Thurnherr
Town:

Allschwill


Phone: +41613078000

Kategorie:

Research & Development



Diese Pressemitteilung wurde bisher 153 mal aufgerufen.


Die Pressemitteilung mit dem Titel:
"Explosionproof emergency stop device"
steht unter der journalistisch-redaktionellen Verantwortung von

thuba AG (Nachricht senden)

Beachten Sie bitte die weiteren Informationen zum Haftungsauschluß (gemäß TMG - TeleMedianGesetz) und dem Datenschutz (gemäß der DSGVO).

Explosionproof signalling devices ...

All explosionproof signalling devices are made of stainless steel, have a diameter of 22 mm and a moulded cable. Signal lamps: These devices can be operated with AC or DC voltage. A built-in current stabilisation guarantees constant brightness over t ...

Explosionproof Communication Devices ...

The explosionproof communication devices are intended for use in Zone 2 (EPL Gc) explosive gas atmospheres according to IEC 60079-0 and IEC 60079-15. The enclosure is designed according to IEC 60079-0 and IEC 60079-31 for use in explosive dust atmosp ...

Explosionproof Buzzer ...

The existing explosionproof signalling devices, such as illuminated pushbuttons, switches, pushbuttons, emergency stop buttons, potentiometers, have been supplemented by a buzzer. The explosionproof buzzer combines a small design with low power consu ...

Alle Meldungen von thuba AG



 

Werbung



Facebook

Sponsoren

foodir.org The food directory für Deutschland
News zu Snacks finden Sie auf Snackeo.
Informationen für Feinsnacker finden Sie hier.

Firmenverzeichniss

Firmen die firmenpresse für ihre Pressearbeit erfolgreich nutzen
1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z